4 Channels 50nA 97 dB Instrumentational OP Amps 14 Pins CDIP

SOT-23

LT1014MJB Datasheet PDF

non-compliant

Technical Specifications

Parameter NameValue
TypeParameter
Lifecycle Status ACTIVE (Last Updated: 3 days ago)
Mount Through Hole
Package / Case CDIP
Number of Pins 14
PackagingRail/Tube
Number of Terminations 14
ECCN Code EAR99
Max Operating Temperature125°C
Min Operating Temperature -55°C
Subcategory Operational Amplifier
Technology BIPOLAR
Terminal Position DUAL
Number of Functions 4
Supply Voltage 15V
Pin Count14
Temperature GradeMILITARY
Number of Channels 4
Max Supply Voltage44V
Min Supply Voltage5V
Power Dissipation1.375W
Slew Rate0.4 V/μs
Architecture VOLTAGE-FEEDBACK
Amplifier Type OPERATIONAL AMPLIFIER
Common Mode Rejection Ratio 97 dB
Current - Input Bias 50nA
Input Offset Voltage (Vos) 450μV
Gain Bandwidth Product1MHz
Neg Supply Voltage-Nom (Vsup) -15V
Voltage Gain 120dB
Low-Offset NO
Frequency CompensationYES
Max Dual Supply Voltage22V
Low-Bias NO
MicropowerYES
Min Dual Supply Voltage 2.5V
Bias Current-Max (IIB) @25C 0.05μA
Programmable PowerNO
Dual Supply Voltage 15V
Wideband NO
Input Offset Current-Max (IIO) 0.002μA
Height 5.08mm
Length 19.56mm
Width 6.67mm
Thickness 4.57mm
Radiation HardeningNo
RoHS StatusRoHS Compliant
Lead Free Contains Lead
In-Stock:2463 items

LT1014MJB Product Details

LT1014MJB Overview


A CDIP case is used to package the op amp. OPERATIONAL AMPLIFIER-type instrumentation amplifiers are used in this application. The case in which buffer amplifier is delivered is called a Rail/Tube case. It is estimated that there will be 14 terminations in the next few months. There are a total of 14 pins on this op amp. It is important to remember that this op amp should be operated at a voltage of 15V volts. It should be noted that this op amp is a type of Operational Amplifier device. There are 14 pins on this chip. In terms of the input offset voltage, instrumentation amplifier rates at 450μV. There should be no change in the voltage gain. There are 4 channels on the operational amplifiers. In order for op amp to function properly, the temperature should not be lower than -55°C degrees Celsius. Instrumentation amplifier should only be used at temperatures up to 125°C. I would like to point out that this electrical component is capable of working from a voltage below 44V as far as the power supply is concerned. As a general rule, it is advisable to keep the op amp's supply voltage above 5V at all times. The dual supply voltage of 22V should be used for the conduct of this electronic component.

LT1014MJB Features


14 Pins
supply voltage of 15V
120dB voltage gain


LT1014MJB Applications


There are a lot of Texas Instruments
LT1014MJB Instrumentational OP Amps applications.


  • Addition operation circuits
  • Subtraction operation circuits
  • single/dual op amp sum and difference circuits
  • Integrator circuits
  • Differentiator circuits
  • Logarithmic operation circuits
  • Exponential operation circuits
  • Multiplication circuits
  • Division circuits
  • Precision measurement