Welcome to Hotenda.com Online Store!

logo
userjoin
Home

TLV2782AIDG4

TLV2782AIDG4

TLV2782AIDG4

Texas Instruments

23mA per Channel 15pA 50 dB Instrumentational OP Amps 0.0003μA 8 Pins D

SOT-23

TLV2782AIDG4 Datasheet PDF

non-compliant

Technical Specifications

Parameter NameValue
TypeParameter
Package / Case D
Surface MountYES
Number of Pins 8
JESD-609 Code e4
Pbfree Code yes
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Number of Terminations 8
ECCN Code EAR99
Max Operating Temperature125°C
Min Operating Temperature -40°C
Subcategory Operational Amplifier
Packing Method TUBE
Technology CMOS
Terminal FormGULL WING
Peak Reflow Temperature (Cel) 260
Number of Functions 2
Supply Voltage 2.7V
Pin Count8
Number of Elements 2
Temperature GradeAUTOMOTIVE
Max Supply Voltage3.6V
Min Supply Voltage1.8V
Operating Supply Current 650μA
Nominal Supply Current1.54mA
Power Dissipation710mW
Current - Output 23mA
Slew Rate4.3 V/μs
Amplifier Type OPERATIONAL AMPLIFIER
Common Mode Rejection Ratio 50 dB
Current - Input Bias 15pA
Output Current per Channel 23mA
Input Offset Voltage (Vos) 2mV
Bandwidth 8MHz
Gain Bandwidth Product8MHz
Unity Gain BW-Nom 8000 kHz
Voltage Gain 120dB
Average Bias Current-Max (IIB) 0.0003μA
Low-Offset NO
Frequency CompensationYES
Max Dual Supply Voltage1.8V
Low-Bias YES
MicropowerYES
Min Dual Supply Voltage 900mV
Bias Current-Max (IIB) @25C 0.000015μA
Programmable PowerNO
Nominal Gain Bandwidth Product 8MHz
Max I/O Voltage 2mV
Length 4.9mm
Height Seated (Max) 1.75mm
Radiation HardeningNo
RoHS StatusRoHS Compliant
Lead Free Contains Lead
In-Stock:3227 items

TLV2782AIDG4 Product Details

TLV2782AIDG4 Overview


A D case is used to package the op amp. OPERATIONAL AMPLIFIER-type instrumentation amplifiers are used in this application. It is estimated that there will be 8 terminations in the next few months. There are a total of 8 pins on this op amp. It is important to remember that this op amp should be operated at a voltage of 2.7V volts. It should be noted that this op amp is a type of Operational Amplifier device. There are 8 pins on this chip. In terms of the input offset voltage, instrumentation amplifier rates at 2mV. An 650μA volt supply current is needed for this linear amplifier to operate. There should be no change in the voltage gain. In order for op amp to function properly, the temperature should not be lower than -40°C degrees Celsius. Instrumentation amplifier should only be used at temperatures up to 125°C. There are a total of 2 elements in this linear amplifier. The instrumentation amplifier is packed in the form of TUBE. I would like to point out that this electrical component is capable of working from a voltage below 3.6V as far as the power supply is concerned. As a general rule, it is advisable to keep the op amp's supply voltage above 1.8V at all times. The dual supply voltage of 1.8V should be used for the conduct of this electronic component.

TLV2782AIDG4 Features


8 Pins
supply voltage of 2.7V
120dB voltage gain


TLV2782AIDG4 Applications


There are a lot of Texas Instruments
TLV2782AIDG4 Instrumentational OP Amps applications.


  • Addition operation circuits
  • Subtraction operation circuits
  • single/dual op amp sum and difference circuits
  • Integrator circuits
  • Differentiator circuits
  • Logarithmic operation circuits
  • Exponential operation circuits
  • Multiplication circuits
  • Division circuits
  • Precision measurement

Get Subscriber