Texas Instruments

2 Channels 80 dB Instrumentational OP Amps 0.5μA 10 Pins

SOT-23

5962R9679802VHA Datasheet PDF

non-compliant

Technical Specifications

Parameter NameValue
TypeParameter
Lifecycle Status ACTIVE (Last Updated: 1 week ago)
Mount Surface Mount
Number of Pins 10
PackagingRail/Tube
JESD-609 Code e0
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN Code EAR99
Terminal Finish Tin/Lead (Sn/Pb)
Max Operating Temperature125°C
Min Operating Temperature -55°C
Terminal Position DUAL
Terminal FormFLAT
Peak Reflow Temperature (Cel) NOT SPECIFIED
Number of Functions 2
Supply Voltage 15V
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Pin Count10
Qualification StatusQualified
Output Type OPEN-COLLECTOR
Temperature GradeMILITARY
Number of Channels 2
Max Supply Voltage36V
Min Supply Voltage5V
Power Dissipation-Max 500mW
Nominal Supply Current11mA
Power Dissipation500mW
Response Time80 ns
Amplifier Type COMPARATOR
Common Mode Rejection Ratio 80 dB
Input Offset Voltage (Vos) 3.8mV
Neg Supply Voltage-Nom (Vsup) -15V
Average Bias Current-Max (IIB) 0.5μA
Max Dual Supply Voltage18V
Min Dual Supply Voltage 2.5V
Screening Level MIL-PRF-38535 Class V
Height 2.032mm
Length 6.858mm
Width 6.121mm
Thickness 1.778mm
Radiation HardeningYes
RoHS StatusRoHS Compliant
Lead Free Contains Lead
In-Stock:4212 items

5962R9679802VHA Product Details

5962R9679802VHA Overview


An op amp ic of the COMPARATOR type. The op amp is delivered to you in a Rail/Tube case. The pins on this board total to 10 in total. I would like to remind you that this buffer op amp should be powered by an 15V battery. A total of 10 pins are present on the instrumentation amplifier. There is an input offset voltage of 3.8mV for this buffer op amp. As far as the device is concerned, buffer amplifier has 2 channels. One of the many advantages that this linear amplifier has, among many other things, is the fact that it outputs OPEN-COLLECTOR signals. For the buffer op amp to operate properly, it must be above the temperature of -55°C degrees Celsius. No temperature greater than 125°C should be used. In terms of the supply voltage, this electrical part is capable of operating at low voltage levels of under 36V. A high supply voltage of more than 5V is recommended for the instrumentation amplifier's supply voltage. As a rule of thumb, you should conduct this electronic part under a dual voltage supply of 18V volts.

5962R9679802VHA Features


10 Pins
supply voltage of 15V
Output Type: OPEN-COLLECTOR


5962R9679802VHA Applications


There are a lot of Texas Instruments
5962R9679802VHA Instrumentational OP Amps applications.


  • Integrator circuits
  • Differentiator circuits
  • Logarithmic operation circuits
  • Exponential operation circuits
  • Multiplication circuits
  • Division circuits
  • Precision measurement
  • Power control
  • Information processing
  • Weak signal detection

Get Subscriber