MLX91206LDC-CAL-002-SP Overview
For safety purposes, the current sensors are housed in 8-SOIC (0.154, 3.90mm Width) packages. Current sensors are packaged in Bulk in order to avoid damage to the devices. It is recommended that these current sensors provide no more than 12mA amps of current. A current sensor should provide a current no greater than 12mA. This current sensor must function at temperatures greater than -40°C at all times. Nonetheless, the maximum operating temperature for the current sensors should be set to 150°C.
MLX91206LDC-CAL-002-SP Features
Moisture Sensitivity Level: 3 (168 Hours)
Operating Temperature: -40°C~150°C
1 Channels
Mounting Type: Surface Mount
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 5V
Frequency: DC~90kHz
Sensing Current: 10mT
8-SOIC (0.154, 3.90mm Width) Package
MLX91206LDC-CAL-002-SP Applications
There are a lot of Melexis Technologies NV
MLX91206LDC-CAL-002-SP Current Sensors applications.
- Overcurrent Detection
- Frequency, Voltage, and Solar Inverters
- Electrical drives
- General purpose inverters
- AC variable speed drives
- Static converters for DC motor drives
- Battery supplied applications
- Uninterruptible Power Supplies(UPS)
- Switched Mode Power Supplies(SMPS)
- Power supplies for welding applications