HTB 100-P Overview
A Module, Single Pass Through package is used to protect the current sensors from damage. The devices are protected from damage by the Tray package. It is recommended that these current sensors supply a maximum current of 15mA.
HTB 100-P Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -40°C~80°C
1 Channels
Sensor Type: Hall Effect, Open Loop
Supply Voltage: ±12V~15V
Frequency: DC~50kHz
Sensing Current: 100A
Module, Single Pass Through Package
HTB 100-P Applications
There are a lot of LEM USA Inc.
HTB 100-P Current Sensors applications.
- Power factor correction
- Overcurrent protection
- DC and AC power monitoring
- Closed-L oop DC- and AC-Current Sensor Modules
- Leakage Current Sensors
- Industrial Monitoring and Control Systems
- Overcurrent Detection
- Frequency, Voltage, and Solar Inverters
- Electrical drives
- General purpose inverters