HO 10-P/SP33 Overview
In order to ensure safety, the current sensors are placed in Module, Single Pass Through packages. As a precaution, these current sensors are packaged in the Tray to protect them from damage. This current sensor should be able to supply a maximum current of 25mA.
HO 10-P/SP33 Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -40°C~105°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 3.3V
Frequency: DC~250kHz
Sensing Current: 10A
Module, Single Pass Through Package
HO 10-P/SP33 Applications
There are a lot of LEM USA Inc.
HO 10-P/SP33 Current Sensors applications.
- Overcurrent protection
- DC and AC power monitoring
- Closed-L oop DC- and AC-Current Sensor Modules
- Leakage Current Sensors
- Industrial Monitoring and Control Systems
- Overcurrent Detection
- Frequency, Voltage, and Solar Inverters
- Electrical drives
- General purpose inverters
- AC variable speed drives