RTY070HVNAX Overview
Linear position measuring sensors are packaged in Box with Connector packages to protect them. The electronic component is packaged in the Bulk. Linear position measurement sensors have 3 pins. The supply voltage applied by the linear position measuring sensor should be 30V when it operates. An electric circuit with a linear position measuring sensor cannot have a supply voltage higher than 30V. In a DC circuit, however, the supply voltage applied by the linear position measuring sensor cannot be lower than 10V. A linear position measuring sensor cannot produce a voltage below 500mV.
RTY070HVNAX Features
Supply Voltage: 10V~30V
Operating Temperature: -40°C~125°C
RTY Series
Mount: Chassis Mount
Package / Case: Box with Connector
Mounting Type: Chassis Mount
3 Pins
RTY070HVNAX Applications
There are a lot of Honeywell Sensing and Productivity Solutions RTY070HVNAX Angle & Linear Position Measuring Sensors applications.
- Wire- die bonding machines
- HVAC damper control
- Dishwasher control systems
- Non-Contacting Potentiometer
- Knob position sensors
- Cylinder and valve position sensing
- Rotary encoders
- Irrigation equipment pivot control
- Linear movement measurement,
- Battery-powered applications