NSCSHHN001PDUNV Overview
As a convenience, this transducer is included in 4-SIP, Dual Ports, Same Side. Temperature should be set at -40°C~85°C on transducers in order for them to work reliably. Obtaining a 1.5V~12V supply voltage is not a problem for the transducers. To ensure proper operation of the transducers, it is necessary to connect the 4 pins. A nominal supply current of 1.5mA can run the transducers normally. If the transducer is designed to operate continuously at the rated ambient temperature, then the DC voltage should be 5V.
NSCSHHN001PDUNV Features
Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 4-SIP, Dual Ports, Same Side
Operating Temperature: -40°C~85°C
4 Pins
TruStability® NSC series
Operating Pressure: ±1PSI (±6.89kPa)
Operating Supply Voltage: 5V
NSCSHHN001PDUNV Applications
There are a lot of Honeywell Sensing and Productivity Solutions
NSCSHHN001PDUNV Transducers applications.
- Hydrogen Storage
- Refrigerant pressure monitoring in HVAC/R systems
- Dry air system pressure, process controls and automation
- Dry air system monitoring
- Hydraulic, brake, and engine oil fluid pressure monitoring
- Air brake pressure monitoring
- Vertical velocity indication (e.g. rise/sink speed)
- Internet of things
- Enhancement of GPS navigation
- Indoor navigation & localization (floor detection, elevator detection)