Welcome to Hotenda.com Online Store!

logo
userjoin
Home

MLH500PSB01B

MLH500PSB01B

MLH500PSB01B

Honeywell Sensing and Productivity Solutions

MLH Series Sealed Gauge Pressure Sensor Analog Current -40°C~125°C 500PSI (3447.38kPa) Threaded ±0.25% 4 mA ~ 20 mA 9.5V~30V Amplified Output, Temperature Compensated

SOT-23

MLH500PSB01B Datasheet PDF

non-compliant

Technical Specifications

Parameter NameValue
TypeParameter
Factory Lead Time 10 Weeks
Mount Stud
Package / Case Cylinder, Metal
Number of Pins 3
Weight 57g
Operating Temperature-40°C~125°C
PackagingBulk
Series MLH
Published 2011
Feature Amplified Output, Temperature Compensated
Part StatusActive
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Applications Industrial Automation
Additional FeatureIP 65, REVERSE VOLTAGE PROTECTION
Voltage - Rated DC 30V
Voltage - Supply 9.5V~30V
Output 4 mA ~ 20 mA
Termination Style Packard Metripak 150
Output Type Analog Current
Output Current4mA
Accuracy ±0.25%
Response Time2 ms
Operating Pressure500PSI (3447.38kPa)
Pressure Type Sealed Gauge
Port Style Threaded
Port Size Male - 1/4 6.35mm NPT
Maximum Pressure 1500PSI (10342.14kPa)
Sensors/Transducers Type PRESSURE SENSOR,STRAIN GUAGE
Housing PLASTIC
Max Pressure 1500 PSI
Pressure Sensing Mode GAGE
Height 55mm
Length 27mm
Width 27mm
RoHS StatusRoHS Compliant
Lead Free Lead Free
In-Stock:87 items

Pricing & Ordering

QuantityUnit PriceExt. Price
1$133.580000$133.58
10$126.018868$1260.18868
100$118.885724$11888.5724
500$112.156344$56078.172
1000$105.807872$105807.872

MLH500PSB01B Product Details

MLH500PSB01B Overview


In order to make your life easier, a Cylinder, Metal package includes this transducer. If you want reliable results, you should set the transducers' temperature to -40°C~125°C. Supply voltages as low as 9.5V~30V work well with the transducers. 3 pins must be connected in order for the transducer to work properly. Electronic components like this are packaged in Bulk packages. For continuous operation of the transducers at ambient temperatures, DC voltage should be 30V. If the transducers are working properly, the output current should be 4mA.

MLH500PSB01B Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Cylinder, Metal
Operating Temperature: -40°C~125°C
3 Pins
MLH series
Operating Pressure: 500PSI (3447.38kPa)


MLH500PSB01B Applications


There are a lot of Honeywell Sensing and Productivity Solutions
MLH500PSB01B Transducers applications.


  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring
  • Air brake pressure monitoring
  • Vertical velocity indication (e.g. rise/sink speed)

Get Subscriber