MLH250PGB06G Overview
Cylinder, Metal includes this transducer for convenience. Reliable performance can be assured by setting the transducers to -40°C~125°C. A supply voltage of 8V~30V is sufficient for the transducers to operate well. To make the transducers work, you must connect the pins at 3. In this package, there is an electronic component that looks like a Bulk. A nominal supply current of 5mA can make the transducers operate normally. Transducers must release 4V voltage to work. The current of the transducers should not exceed 17mA, otherwise it will be dangerous.
MLH250PGB06G Features
Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Cylinder, Metal
Operating Temperature: -40°C~125°C
3 Pins
MLH series
Operating Pressure: 250PSI (1723.69kPa)
MLH250PGB06G Applications
There are a lot of Honeywell Sensing and Productivity Solutions
MLH250PGB06G Transducers applications.
- Leisure, Sports, and Fitness Activity Identification
- Weather Forecasting
- Hydrogen Storage
- Refrigerant pressure monitoring in HVAC/R systems
- Dry air system pressure, process controls and automation
- Dry air system monitoring
- Hydraulic, brake, and engine oil fluid pressure monitoring
- Air brake pressure monitoring
- Vertical velocity indication (e.g. rise/sink speed)
- Internet of things