TruStability® HSC Series Vented Gauge Pressure Sensor SPI -20°C~85°C 23.21PSI (160kPa) Barbed ±0.25% 12 b 3V~3.6V Amplified Output, Temperature Compensated

SOT-23

HSCMAND1.6BGSA3 Datasheet PDF

non-compliant

Technical Specifications

Parameter NameValue
TypeParameter
Factory Lead Time 9 Weeks
Package / Case 8-SMD, J-Lead, Top Port
Surface MountYES
Mounting FeatureSURFACE MOUNT
Number of Pins 8
Operating Temperature-20°C~85°C
Series TruStability® HSC
Feature Amplified Output, Temperature Compensated
Part StatusActive
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination SMD/SMT
Applications Board Mount
Voltage - Rated DC 3.3V
Voltage - Supply 3V~3.6V
Output 12 b
Termination Style J Lead
Output Type SPI
Operating Supply Voltage3.3V
Nominal Supply Current1.6mA
Max Supply Current 2.1mA
Number of Bits 12
Accuracy ±0.25%
Response Time1 ms
Operating Pressure23.21PSI (160kPa)
Pressure Type Vented Gauge
Port Style Barbed
Port Size Male - 0.19 4.93mm Tube
Maximum Pressure 58.02PSI (400kPa)
Sensors/Transducers Type PRESSURE SENSOR,PEIZORESISTIVE
Housing CERAMIC
Max Pressure 58.02 PSI
Pressure Range-Max 23.206 Psi
Pressure Sensing Mode GAGE
RoHS StatusRoHS Compliant
In-Stock:164 items

Pricing & Ordering

QuantityUnit PriceExt. Price
1$95.280000$95.28
10$89.886792$898.86792
100$84.798861$8479.8861
500$79.998925$39999.4625
1000$75.470684$75470.684

HSCMAND1.6BGSA3 Product Details

HSCMAND1.6BGSA3 Overview


As a convenience, the transducer is included in package 8-SMD, J-Lead, Top Port. Reliable performance is ensured by setting the transducer temperature to -20°C~85°C. With a voltage supply of 3V~3.6V, the transducers can function properly. There is a requirement for connecting the 8 pins to make the transducer work properly. This transducer can handle pressures up to 23.206 Psi. Transducers working with 1.6mA supply current can function normally. For the transducers to continuously work at the rated ambient temperature, DC voltage should be 3.3V. The current of the transducers should not exceed 2.1mA, otherwise it will be dangerous.

HSCMAND1.6BGSA3 Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 8-SMD, J-Lead, Top Port
Operating Temperature: -20°C~85°C
8 Pins
TruStability® HSC series
Operating Pressure: 23.21PSI (160kPa)
Operating Supply Voltage: 3.3V


HSCMAND1.6BGSA3 Applications


There are a lot of Honeywell Sensing and Productivity Solutions
HSCMAND1.6BGSA3 Transducers applications.


  • Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
  • Vertical velocity monitoring
  • Leisure, Sports, and Fitness Activity Identification
  • Weather Forecasting
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Dry air system pressure, process controls and automation
  • Dry air system monitoring
  • Hydraulic, brake, and engine oil fluid pressure monitoring
  • Air brake pressure monitoring