141PC05GW103 Overview
It has been included as part of the Module package in the interest of convenience. Ensure reliability by setting the transducers' temperature to -40°C~85°C. With a supply voltage of 7V~16V the transducers can operate effectively. In order for the transducers to work, the 5 pins need to be connected. Presented in a Bulk package, this electronic component contains the following features. The current of the transducers should not exceed 20mA, otherwise it will be dangerous.
141PC05GW103 Features
Package / Case: Module
Operating Temperature: -40°C~85°C
5 Pins
140PC series
Operating Pressure: -5PSI (-34.47kPa)
141PC05GW103 Applications
There are a lot of Honeywell Sensing and Productivity Solutions
141PC05GW103 Transducers applications.
- Hydrogen Storage
- Refrigerant pressure monitoring in HVAC/R systems
- Dry air system pressure, process controls and automation
- Dry air system monitoring
- Hydraulic, brake, and engine oil fluid pressure monitoring
- Air brake pressure monitoring
- Vertical velocity indication (e.g. rise/sink speed)
- Internet of things
- Enhancement of GPS navigation
- Indoor navigation & localization (floor detection, elevator detection)