CR4410-150 Overview
As a safety precaution, current sensors are placed in Module packages. The current sensors are packaged in the Bulk in order to prevent damage to the devices. It is recommended that these current sensors supply a maximum current of 40mA. There should not be an increase in current supplied by current sensors above 40mA. To ensure that these current sensors work, the operating temperature cannot be less than 0°C. The current sensors should remain at 60°C for the maximum operating temperature.
CR4410-150 Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: 0°C~60°C
1 Channels
Mounting Type: DIN Rail, Panel
Sensor Type: Transformer w/Conditioning
Supply Voltage: 24V
Frequency: 50Hz~400kHz
Sensing Current: 150A
Module Package
CR4410-150 Applications
There are a lot of CR Magnetics Inc. CR4410-150 Current Sensors applications.
- DC and AC power monitoring
- Switched Mode Power Supplies(SMPS)
- Inverter and H-bridge current measurements
- Home Automation
- DC motor drives
- Battery supplied applications
- AC variabel speed drives and servo motor drives
- Overcurrent protection
- Battery supplied applications
- Battery chargers and systems