CR4120-5 Overview
To ensure safety, current sensors are encapsulated in Module packages. Current sensors are packaged in Bulk in order to avoid damage to the devices. These current sensors should be able to deliver a maximum current of 40mA. A current sensor's supply current should not exceed 40mA. If these current sensors are to function, their operating temperatures cannot be lower than 0°C. It is recommended that the maximum operating temperature of the current sensors is set to 60°C.
CR4120-5 Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: 0°C~60°C
1 Channels
Mounting Type: DIN Rail, Panel
Sensor Type: Transformer w/Conditioning
Supply Voltage: 24V
Frequency: 20Hz~5kHz
Sensing Current: 5A
Module Package
CR4120-5 Applications
There are a lot of CR Magnetics Inc. CR4120-5 Current Sensors applications.
- Overcurrent protection
- General purpose inverters
- Closed-L oop DC- and AC-Current Sensor Modules
- Power factor correction
- Mobile applications
- Power supplies for welding applications
- Inverter and H-bridge current measurements
- Industrial Monitoring and Control Systems
- Uninterruptable Power Supllies (UPS)
- Battery supplied applications