ADCMP392ARZ

Data Sheet

 

ADCMP392

 

 

THEORY OF OPERATION 

BASIC COMPARATOR 

In its most basic configuration, a comparator can be used to 
convert an analog input signal to a digital output signal (see 
Figure 21). The analog signal on INx+ is compared to the 
voltage on INx−, and the voltage at OUTx is either high or low, 
depending on whether INx+ is at a higher or lower potential 
than INx−, respectively.  

 

Figure 21. Basic Comparator and Input and Output Signals  

RAIL-TO-RAIL INPUT (RRI) 

Using a CMOS nonRRI stage (that is, a single differential pair) 
limits the input voltage to approximately one gate-to-source 
voltage (V

GS

) away from one of the supply lines. Because V

GS

 for 

normal operation is commonly more than 1 V, a single differential 
pair input stage comparator greatly restricts the allowable input 
voltage. This restriction can be quite limiting with low voltage 
supplies. To resolve this issue, RRI stages allow the input signal 
range to extend up to the supply voltage range. In the case of 
the

ADCMP392

, the inputs continue to operate 200 mV beyond 

the supply rails. 

OPEN-DRAIN OUTPUT 

The 

ADCMP392

 has an open-drain output stage that requires 

an external resistor to pull up to the logic high voltage level 
when the output transistor is switched off. The pull-up resistor 
must be large enough to avoid excessive power dissipation, but 
small enough to switch logic levels reasonably quickly when the 
comparator output is connected to other digital circuitry. The 
rise time of the open-drain output depends on the pull-up 
resistor (R

PULLUP

) and load capacitor (C

L

) used. 

The rise time can be calculated by  

t

R

 = 2.197 R

PULLUP

 C

L

 

(1) 

 

POWER-UP BEHAVIOR 

On power-up, when V

CC

 reaches 0.9 V, the 

ADCMP392

 is 

guaranteed to assert an output low logic. When the voltage on 
the V

CC

 pin exceeds UVLO, the comparator inputs take control. 

CROSSOVER BIAS POINT 

Rail-to-rail inputs of this type of architecture, in both op amps 
and comparators, have a dual front-end design. PMOS devices 
are inactive near the V

CC

 rail, and NMOS devices are inactive near 

GND. At some predetermined point in the common-mode range, a 
crossover occurs. At this point, normally 0.8 V and V

CC

 − 0.8 V, the 

measured offset voltages change. 

COMPARATOR HYSTERESIS 

In noisy environments, or when the differential input amplitudes 
are relatively small or slow moving, adding hysteresis (V

HYST

) to 

the comparator is often desirable. The transfer function for a 
comparator with hysteresis is shown in Figure 22. As the input 
voltage approaches the threshold (0 V in Figure 22) from below 
the threshold region in a positive direction, the comparator 
switches from low to high when the input crosses +V

HYST

/2. The 

new switch threshold becomes −V

HYST

/2. The comparator remains 

in the high state until the −V

HYST

/2 threshold is crossed from 

below the threshold region in a negative direction. In this 
manner, noise or feedback output signals centered on the 0 V 
input cannot cause the comparator to switch states unless it 
exceeds the region bounded by ±V

HYST

/2. 

 

Figure 22. Comparator Hysteresis Transfer Function 

 
 
 
 
 
 

 

OUT

V

IN

V

REF

INx+

INx–

V

CC

V+

V+

V

REF

V

IN

V

OUT

0V

t

12207-

019

OUTPUT

INPUT

0V

V

OL

V

OH

+V

HYST

2

–V

HYST

2

12207-

020

Rev. 0 | Page 9 of 15 