EP5358LUI

 

 

EP5358LUI/EP5358HUI

 

 

Layout Recommendation 

Figure 10  shows  critical components and layer 
1 traces of a recommended minimum footprint 
EP5358LQI/EP5358HQI  layout with ENABLE 
tied to V

IN

. Alternate ENABLE configurations, 

and other small signal pins need to be 
connected and routed according to specific 
customer application. Please see the Gerber 
files on the Altera 

website 

www.altera.com/enpirion

  for exact dimensions 

and other  layers.  Please refer to Figure 10 
while reading the layout recommendations in 
this section. 

Recommendation 1:  Input and output filter 
capacitors should be placed on the same side 
of the PCB, and as close to the EP5358QI 
package as possible. They should be 
connected to the device with very short and 
wide traces. Do not use thermal reliefs or 
spokes when connecting the capacitor pads to 
the respective nodes. The +V and GND traces 
between the capacitors and the EP5358QI 
should be as close to each other as possible 
so that the gap between the two nodes is 
minimized, even under the capacitors. 

Recommendation 2: Input and output grounds 
are separated until they connect at the PGND 
pins. The separation shown on Figure 10 
between the input and output GND circuits 
helps minimize noise coupling between the 
converter input and output switching loops. 

Recommendation 3: The system ground 
plane should be the first layer immediately 
below the surface layer. This ground plane 
should be continuous and un-interrupted below 
the converter and the input/output capacitors. 
Please see the Gerber files on the Altera 
website 

www.altera.com/enpirion

 

Figure 10:Top PCB Layer Critical Components 

and Copper for Minimum Footprint 

Recommendation 4: Multiple small vias 
should be used to connect the ground traces 
under the device to the system ground plane 
on another layer for heat dissipation. The drill 
diameter of the vias should be 0.33mm, and 
the vias must have at least 1 oz. copper plating 
on the inside wall, making the finished hole 
size around 0.20-0.26mm. Do not use thermal 
reliefs or spokes to connect the vias to the 
ground plane. It is preferred to put these vias 
under the capacitors along the edge of the 
GND copper closest to the +V copper. Please 
see Figure 10. These vias connect the 
input/output filter capacitors to the GND plane 
and help reduce parasitic inductances in the 
input and output current loops. If the vias 
cannot be placed under C

IN

  and C

OUT

, then put 

them just outside the capacitors along the 
GND. Do not use thermal reliefs or spokes to 
connect these vias to the ground plane. 

Recommendation 5: AVIN is the power supply 
for the internal small-signal control circuits. It 
should be connected to the input voltage at a 
quiet point. In Figure 10 this connection is 
made  at the input capacitor close to the V

IN

 

connection. 

 

 

www.altera.com/enpirion

  Page 14 

 

03541

October 11, 2013

Rev F