VOUT

OLD

 is the VID  table output voltage. 

 
 
For a given  Rs Value,  the VOUT

NEW

 for VID 

settings is determined by the following 
equations:   
 
EP5358LUI: 

Volts

Rs

VOUT

VOUT

L

OLD

NEW

+

=

1

711

 

 

EP5358HUI: 

Volts

Rs

VOUT

VOUT

H

OLD

NEW

+

=

1

356

 

 
NOTE: The amount of adjustment is limited to 
approximately 15% of the nominal VID setting.  
 
NOTE:  Adjusting  VOUT using this method will 
increase the tolerance of the output voltage.   
The larger the adjustment, the greater the 
increase in tolerance. 
 

Power-Up/Down Sequencing 

During power-up, ENABLE should not be 
asserted before PVIN, and PVIN should not be 
asserted before AVIN.  The PVIN should never 
be powered when AVIN is off.  During power 
down, the AVIN should not be powered down 
before the PVIN. Tying PVIN and AVIN or all 
three pins (AVIN, PVIN, ENABLE) together 
during power up or power down meets these 
requirements

Pre-Bias Start-up 

The EP5358xUI does not support startup into a 
pre-biased condition. Be sure the output 
capacitors are not charged or the output of the 
EP5358xUI is not  pre-biased  when the 
EP5358xUI  is first enabled. 

 

Input Filter Capacitor 

For I

LOAD

 

≤ 500mA, C

IN

 = 2.2uF 

For I

LOAD

 > 500mA  C

IN

 = 4.7uF. 

 
0402  capacitor case size is acceptable. 
 
The input capacitor must use a X5R or X7R or 
equivalent dielectric formulation.  Y5V or 
equivalent dielectric formulations lose 
capacitance with frequency, bias, and with 
temperature, and are not suitable for switch-
mode DC-DC converter input  filter applications.     

Output Filter Capacitor 

For VIN 

≤ 4.3V, C

OUT_MIN

 = 10uF 0603 MLCC.   

For VIN  > 4.3V,  C

OUT_MIN

 = 10uF 0805 MLCC.   

 Ripple performance can be improved by using 
2x10µF 0603 MLCC capacitors  (for any 
allowed VIN). 

The maximum output filter capacitance next to 
the output pins of the device is 60µF low ESR 
MLCC capacitance.  V

OUT

  has to be sensed at 

the last output filter capacitor next to the 
EP5358xUI. 

Additional bulk capacitance for decoupling and 
bypass can be placed at the load as long as 
there is sufficient separation between the V

OUT

 

Sense point and the bulk capacitance. 

Excess total capacitance on the output (Output 
Filter + Bulk) can cause an over-current 
condition at startup.  Refer to the section on 
Soft-Start for the maximum total capacitance 
on the output. 

The output capacitor must use a X5R or X7R 
or equivalent dielectric formulation.  Y5V or 
equivalent dielectric formulations lose 
capacitance with frequency, bias, and 
temperature and are not suitable for switch-
mode DC-DC converter output filter 
applications. 

 

 

 

www.altera.com/enpirion

  Page 13 

 

03541

October 11, 2013

Rev F